Ecaro25 features the unique fireextinguishing agent fe25 by duponttm. The total energy at any particular point, above some arbitrary horizontal datum plane, is equal to the sum of the elevation. May 25, 20 aslong as nozzle selection, pipe size and pipe length limitations are adhered to, hydraulic flow calculations are notrequired. Basic requirement for fire suppression piping ecaro25.
The highx shx and dux afp air technologies gaseous extinguishing system pressure relief vents are the highest performing vents in the world. Design pipe layouts based on flow calculations and suppression requirements. Ecaro25 is perfect for new clean agent fire suppression applications, as well as for halon replacement projects. The suggested design practice is to start with a design concentration of 8. Chemours brings a history of leadership in fire protection, making it a driving force in the development of safe, clean alternatives to commonly used fire suppression systems in military applications. Engineered system concept these systems are designed within the basic parameters outlined in this manual,and their performance is evaluated with the assistance of the fike flow calculation program.
The clean agent is retained in the container by a impulse valve assembly which contains a fastacting rupture disc. Protect valuable equipment, people and assets with a clean agent fire suppression system using 3m novec 1230 fire protection fluid. In fact, the micromist system releases 100 times less water than traditional sprinkler systems, yet effectively extinguishes the fire. The decision to use the proinert2 technology was an easy one due to the proven performance of the constant flow valve technology which has been on the market for 7 plus years. The most popular version of this product among our users is 4. And ecaro25 is 15% more efficient in hold time than a hfc227 ea or fm200 fire suppression systems, and 25% more efficient than a fk5112 system. Identify the suppression characteristics of ecaro25.
The selection of nozzles is generally determined by the amount of ecaro25 agent required flow rate versus the flow rate. Fike s ecaro25 clean agent fire protection system requires 20% less clean agent per cubic footmeter than hfc227ea or fm200 clean agent fire suppression systems and an incredible 38% less clean agent than fk5112 thats a significant cost savings. Bursting disc sizing methodologies all sizing equations for pressure relief devices are derived from the general bernoulli equations for flow of liquids, steam and vapour. Bernoullis theorem is a means of expressing the application of the law of conservation of energy to the flow of fluids in a conduit piping.
Engineered hydraulic flow program used to predict the two phase flow of fm200 through a pipe network contacts should any part of this manual not be understood, or there are any queries concerning a system, please contact. This highly effective fire suppression system is safe for people, assets and the environment. The fike proinert2 system, due to its constant flow valve technology was selected to protect the next dc data centre facilities around australia. Fike creates and manufactures industryleading solutions for reliable safety and uncompromising protection of people and assets. For floor loading information refer to the table on page 6 or to fikes ecaro25 flow calculation program for container size and actual fill weight being. Retrofitted nonhalon fire suppression system and method. The liquid level indicator lli must be installed while the container is empty. Hfc227ea clean agent fire suppression system even one day lost to firerelated downtime can result in lost revenues, customers and profits. The individual sections of pipe and each fitting to be used, corresponding to isometric drawings.
Just drop in new nozzles and containers and youre back in business withecaro25from fike. Mitigating fire risks in mission critical facilities. Vision to eliminate catastrophic loss of life and assets for companies around the world. Free essays, homework help, flashcards, research papers, book reports, term papers, history, science, politics. Here you may download fike software and pricing toolboxes. The hazard being protected can be any size, shape or volume, provided that the hazard being protected is within the limitations described in this manual. That translates into less runoff, less damage and easy cleanup. Architects specifications the nozzle used to disperse clean agent shall be a fike series 80 nozzle. Download fm200 gas suppression system flow calculation. Complete hydraulic flow calculations, from fike s ulfm approved ecaro25 flow calculation program, shall be provided for all engineered clean agent systems. The ecaro25 flow calculation software also generates new nozzle specifications to replace the existing halon 1 nozzles. An ecaro25 clean agent fire suppression system is the superior, costeffective choice for protecting electronics and highvalue assets reducing the threat of needless downtime and business interruption. Macron safety systems uk limited burlingham house hewett road gapton hall industrial estate great yarmouth norfolk. Ecaro25 clean agent fire suppression system hfc125 fike.
The name of the program executable file is ecaro25. Fire suppressants the fire protection modern businesses need. Fm200 gas suppression system flow calculation full version, full download, premium download, licensed copy. Pressure relief vents gas suppression fire protection. The latest version of fike clean agent system flow calculation software is currently unknown. Data sheet engineered nozzles for ecaro25 description the function of the fike discharge nozzle is to control the agent flow and distribute the agent throughout the protected enclosure in a uniform, predetermined pattern and concentration. Combined with the latest in microprocessor based electronic detection and pcbased fire management systems, master automated provides. For floor loading information refer to the table on page 6 or to fikes ecaro25 flow calculation program for container size and actual fill weight being supplied. Fe25 absorbs heat energy at its molecular level faster than the heat can be generated,so the fire cannot sustain itself. Full text of asia pacific fire 2010 internet archive. This head loss is included in the overall system loss calculations to determine the size of the relief system.
Data sheet agent storage containers with hfc227ea description fike clean agent containers are used in fire extinguishing systems to store the clean agent until a fire develops and the agent must be released. It was initially added to our database on 10222014. Schneider electric data center science center white paper 83 rev 2 4 mitigating fire risks in mission critical facilities 60 area per detector ft2 125 area per detector m2 11. Resistant to flow method k r the k r represents the velocity head loss due to the rupture disc device. Fike clean agent system flow calculation software is a shareware software in the category miscellaneous developed by fike clean agent system flow calculation software. Free fike ecaro25 flow calculation download fike ecaro. Ecaro25, utilizing hfc125 dupont fe25 as the fireextinguishing agent, is the best, most costeffective clean agent fire protection system available.
The ecaro25 flow calculation software will verify if the existing pipe network can remain as is. The fike discharge nozzle used shall be factory mutual fm approved and underwriters laboratory ul listed. Fike corporation expedited the delivery of the new hardware to the job site with a oneday turn around, and the fire protection system was brought. The basis for an optimal application of gas fire extinguishing systems are the hydraulic equations combining the technical data of the installation components pipe diameters, resistance coefficients of armatures, etc. Fike ecaro25 flow calculation fike corporation software. Ecaro25 flow calculation software kc protrade services inc. Free fike ecaro 25 flow calculation download fike ecaro 25. Fikes clean agent calculator can be accessed and downloaded onto mobile devices, by going to fike is a globally recognized supplier of products and services that protect people and critical assets from dangers such as fire, explosion, and overpressurization. Ecaro 25 flow calculation software supression fire isometric pipe network source.
The individual sections of pipe to be used, as shown on the isometrics, must be identified and included in the calculation. The orifice flow calculator is an easy to use, one page program to assist in sizing an orifice meter and bore size. Kidde ads switchin gauge, supervisory pressure switch for nitrogen download. Nozzle size part number drill size minimum maximum 10mm 80015xxx 1. Jun 22, 2009 ecaro 25 flow calculation software supression fire isometric pipe network djair silva. Free fike ecaro 25 flow calculation download fike ecaro. Jan 17, 2018 maximummaximum nozzle flow rate of 17 lbs. All download links are direct full download from publisher sites or their selected mirrors. Very little effect on the system flow calculations system design fm200 and ecaro25 software packages have.
Total agent discharge time must be shown and detailed by zone. Waterbased fire suppression systems sprinklers are designed to protect people and structures. Hammersmith hospital colruyt supermarkets seeboard offices dupont wins national medal of technology. The pressure relief device is considered to behave similar to an orifice device introducing a certain amount of flow resistance. Free fike ecaro25 flow calculation download fike ecaro25.
Kidde flow calculation software for engineered suppression systems download. Ecaro 25 flow calculation software supression fire isometric pipe network djair silva. Here you may access additional features of this site. Using internal product development, scientific research, and testing and validation capabilities, fike develops applicationspecific solutions consistent with the worlds codes, standards and regulations. Free fike ecaro25 flow calculation download software at updatestar 1,746,000 recognized programs 5,228,000 known versions software. Fike clean agent system flow calculation software download. I need your help to download ecaro25 flow calculation. Fike manufactures industrial safety products that protect people and organizations from combustible dust explosions, pressurerelated explosions and industrial fire hazards. Full text of processor newspaper volume 27 number 23.
Kindly subscribe to download this program for free. Programs for the calculation of shevs and gas extinguishing. A personal computer and active myfike account with internet access is required to enroll. Excessive floor loading may require relocating the containers to a more suitable location.
553 1090 125 970 1452 604 1281 756 933 210 158 681 915 45 294 1241 1124 643 560 740 644 1569 1136 684 207 1094 1098 1382 861 824 736 269 312 1232 350 592 1296 805 663 483 797 1432 1371 957 1254 1201 615